Manual FED Entries / Test Results


Revision 1

Pre Boundary Scan:

ActionStatusComments
Fit Serial No. Done
Visual Inspection OK
Fit 1.5A Fuse Done
Power Supply Short Circuit Check OK Short fixed
Fit Front Panel Done
Fit Shorting Links Done
Check Insertion In Boundary Scan Crate OK Tight Fit!
Check Card Power Up OK All LEDs off

Boundary Scan:

ActionStatusCommentsBoundary Scan File
Boundary Scan 'Ident' Test OK C:\Documents and Settings\James Leaver\My Documents\LabviewVIs\FED_Industy_Test\TestData\BoundayScan_TestFile.txt
Boundary Scan 'Inter' Test OK C:\Documents and Settings\James Leaver\My Documents\LabviewVIs\FED_Industy_Test\TestData\BoundayScan_TestFile.txt

Post Boundary Scan:

ActionStatusComments
Fit Front Panel Serial No. Label Done
Attach 2D Barcode Done No. 947634859070685784
Wire Front Panel Extract Switch Done
Fit Diagonal Air Deflector Done
Plug In Compact Flash Card Done
Power On In System Test Crate Done
Program VME PROM OK
Check Flashing LEDs On FED OK LEDs flashing correctly


Revision 0

Pre Boundary Scan:

ActionStatusComments
Fit Serial No. Done
Visual Inspection OK Shiny
Fit 1.5A Fuse Done
Power Supply Short Circuit Check Fail Short on +12V
Fit Front Panel Unattempted
Fit Shorting Links Unattempted
Check Insertion In Boundary Scan Crate Unattempted
Check Card Power Up Unattempted

Boundary Scan:

ActionStatusCommentsBoundary Scan File
Boundary Scan 'Ident' Test Unattempted
Boundary Scan 'Inter' Test Unattempted

Post Boundary Scan:

ActionStatusComments
Fit Front Panel Serial No. Label Unattempted
Attach 2D Barcode Unattempted
Wire Front Panel Extract Switch Unattempted
Fit Diagonal Air Deflector Unattempted
Plug In Compact Flash Card Unattempted
Power On In System Test Crate Unattempted
Program VME PROM Unattempted
Check Flashing LEDs On FED Unattempted