******************** * General Settings * ******************** *** Current FED settings: FED - Read Route = FED9U_ROUTE_VME FED - DAQ Mode = FED9U_MODE_ZERO_SUPPRESSED FED - Scope Length = 5 FED - Test Register = NORMAL FED - Strip Pedestal = 0 FED - Strip High Threshold = 50 FED - Strip Low Threshold = 50 FED - Crate Number = 0 FED - Slot Number = 16 FED - Clock Source = FED9U_CLOCK_TTC FED - Trigger Source = FED9U_TRIG_TTC *** Current FTE settings: FTE - Trigger State = RANDOM FTE - L1A Period = 400 FTE - L1A Low Rate Period = 40000 FTE - L1A Random Rate = 164 FTE - Minimum Trigger Spacing = 3 FTE - TCS Source = LOCAL_SRC FTE - TCS Status Input Enable = ON *** Current FTE FM settings: FTE FM - Cluster Definition = MULTI_STRIP FTE FM - Cluster Widths File = FTeFrameMakerFiles/FTe_CluWidthDistr_Simulation.txt FTE FM - Digital High Level = 3600 FTE FM - Digital Low Level = 400 FTE FM - Pedestal Level = 1200 FTE FM - Maximum Hit Level = 2050 FTE FM - Minimum Hit Level = 1950 FTE FM - Gaussian Noise Level = 0 ###################################################################### Test 1: Initial settings: Number of triggers to send = 150000 Maximum readout rate (MB/s) = 400 Tracker occupancy percentage = 4 Fed9UEvent error checking enabled System status checking enabled Results For Test 1: Number of triggers sent = 150000 Number of events received = 150000 Time taken = 1561.04 Data rate (MB/sec) = 0.254325 Fraction of samples for which throttle was enabled = 0 Errors: Number of events with Event Number errors = 0 Number of events with Event Length errors = 0 Number of events with Fed9U CRC errors = 0 Number of events with Fed9UEvent construction errors = 0